- PHYSICO-CHEMICAL QUANTITIES LABORATORY
Laboratory Head: Dr.ing. Ioan CÃŽRNEANU
Mobile: 0755068897
- Realises and maintains the units of measurement for physico-chemical quantities
- Disseminates the physico-chemical quantities at national level in accordance with the Mutual Recognition Arrangement for National Measurement Standards and Calibration Certificates
Physico-chemical quantities measured in the laboratory
Reference Materials and Medical Devices Group
- Mass concentration (liquids)
- Molar concentration (liquids)
- Mass fraction (solids)
- pH / pX
- Humidity of solids
- Specific quantities for medical devices
Physico-chemical Quantities Group
- Viscosity
- Liquid density
- Concentration (alcohol, sugar, dissolved oxygen)
- Electrolytic conductivity
- Refraction index
- Humidity of gases
Gas Concentration Group
- Mass fraction (gas mixtures)
- Volume fraction (gas mixtures)
- Molar fraction (gas mixtures)
- Mass concentration (gas mixtures)
- Molar concentration (gas mixtures)
Types of activities and services
- applied scientific research for developing national, primary and reference measurement standards and ensuring traceability to SI units
- promoting the principles of metrology in chemistry (www.irmm.be), developing and using reference materials in physico-chemical measurements (www.virm.net)
- calibration
- metrological verification
- making and certifying reference materials
- tests for pattern approval
- technical assistance
For the full list of calibrations and charges, see the List of measuring means for which the Romanian Bureau Legal Metrology performs calibrations, LE 2016.
Representative types of CERTIFIED REFERENCE MATERIALS for ensuring the traceability of physico-chemical results
Types of measurement standards |
Measuring range |
Unit of measurement |
Extended uncertainty (for k =2) |
Working standard solutions for electrolytic conductivity |
40 ... 5000 |
µS x cm-1 |
2 % (rel) |
Electrolytic conductivity cells |
4,00 ... 9,00 |
1 |
0,02 |
Reference pH buffer solutions
Single-element spectrometric reference materials (Na, K, Cu, Pb, Zn, Ca, etc.) |
1 |
g × dm -3 |
2 % (rel) |
Reference gas mixtures (CO, CO2 , H2 , O2) in gas matrix (air or N2) |
88 × 10 -6 ... 9 × 10 -2 |
1 |
2 × 10 -6 ... 0,1 × 10 -2 |
Mixtures of hydrocarbons in air
at the lower explosion limit |
3,1 × 10 -3 ... 3,7 × 10 -2 |
1 |
30 × 10 -6 ... 4 × 10 -4 |
REFERENCE MATERIALS Group
Main aims
- applied scientific research for developing primary and reference measurement standards and ensuring traceability to the SI units
- promoting the principles of metrology in chemistry (www.irmm.be), developing and using reference materials in physico-chemical measurements (www.virm.net)
- disseminating units of measurement for mass and molar concentration, pH, mass fraction and humidity of solids.
Measuring capabilities
Download the Table of measuring capabilities of the Reference Materials Group in ADOBE PDF format.
Comparisons
Personnel, positions and contact details:
- PhD. Eng. Victor George IONESCU, tel. (004021) 334.48.30 ext. 107; mobile: 0725586462
- PhD. Eng. Mariana Ștefania CREȚU, tel. (004021) 334.48.30 ext. 107; mobile: 0727847938
PHYSICO-CHEMICAL QUANTITIES GROUP
Main aims
- applied scientific research for developing primary and reference measurement standards and ensuring traceability to SI units
- disseminating units of measurement for viscosity, density of liquids, alcohol concentration, electrolytic conductivity, refraction index and humidity of gases.
Measuring capabilities
Download the Table of measuring capabilities of the Physico-chemical Quantities Group in ADOBE PDF format.
Comparisons
Personnel, positions and contact details:
- PhD Eng. Ioan CIRNEANU, head of laboratory, tel. (004021) 334.48.30 ext. 101; e-mail: icirneanu@inm.ro
- Tehn. Gheorghe DIACONU, tel. (004021) 334.48.30 ext. 116
- Eng. Florin BENGA, tel. (004021) 334.48.30 ext. 109; mobile: 0726258990;
e-mail: florin.benga@inm.ro
- Eng. Nedisa DRÄ‚GULIN, tel. (004021) 334.48.30 ext. 109; mobile: 0727847969;
e-mail: nedisa.dragulin@inm.ro
GAS CONCENTRATION GROUP
Main aims
- applied scientific research for developing reference measurement standards and ensuring traceability to SI units
- disseminating units of measurement for volume fraction and gas concentration
Measuring capabilities
Download the Table of measuring capabilities of the Gas Concentration Group in in ADOBE PDF format.
Personnel, positions and contact details:
- Dipl. Eng. Cristina DAVID, tel. (004021) 334.48.30 ext. 187
- Ing. Dan BARDAȘU, tel. (004021) 3344830 / 187; mobile: 0727847872; e-mail: dan.bardasu@inm.ro
IONIZING RADIATIONS GROUP
Quantities measured in the frames of the group:
- Activity
- Activity per unit surface
- Exposure
- Absorbed dose
- Dose equivalent
- Exposure rate
- Absorbed dose rate
- Dose equivalent rate
Main aims:
- applied scientific research for developing primary and reference measurement standards and ensuring traceability to the SI units
- promoting the principles of metrology in protection against ionizing radiation
- disseminating units of measurement for activity, activity per unit surface, exposure, absorbed dose, dose equivalent, exposure rate, absorbed dose rate, dose equivalent rate
Physical quantity |
Unit of measure |
Measurement range |
Expanded uncertainty (k=2) |
Traceability route |
Activity |
Bq |
10...109 |
5...8% |
IFIN-HH |
Superficial activity |
Bq · cm-2 |
10...109 |
6...9% |
IFIN-HH |
Exposure, absorbed, equivalent Dose |
Gy
Sv |
10-6...2
10-6...3 |
4,5...7%
4,5...7% |
PTB |
Exposure, Absorbed, Dose equivalent rate |
Gy· s-1
Sv· s-1 |
10-6...2
10-6...3 |
4,5...7%
4,5...7% |
PTB |
Personnel, positions and contact details:
- Dipl. Eng. George LAZAR, tel. (004021) 334.48.30 ext. 156; mobile: 0725945998